Grand Canyon Two-Burner 42-inch Indoor Vented Natural Gas Burner 2BRN-42 Review
Looking for a two-burner that provides sufficient heat and a vivid-looking log that is available in Natural Gas? Get your Grand Canyon Two-Burner 42-inch Indoor Vented Natural Gas Burner 2BRN-42
| Ready to Ship | Proudly Made in the USA | Fastest Delivery |
Grand Canyon 2 Burner System provides a high-quality burner component to help complete your ideal gas fireplace. Grand Canyon's 2 Burner system features a 304 stainless steel chassis for ultimate durability and performance while allowing for gas to flow in from either side of the burner. With 1 main back burner and 1 front, or ember burner, this component is sure to create enough heat to give your living space a much more comfortable atmosphere while the burner tines can be raised or lowered depending on the size of your fireplace opening and preferred log style.
This burner package comes complete with metal bar stock and burner pipes, lava rock, necessary fittings, a flex line, and the ember damper clamp. With (8) different burner size options and propane or natural gas option, Grand Canyon has ensured a burner that will fit any style of indoor living space, allowing you to achieve an area that your friends and family will love for years to come.
Vented Burners - 100% American manufactured burners listed and tested to the ANSI standard. Indoor burners feature stainless steel pan construction with metal bar stock and burner pipes.
Note: Logs not included (Sold Separately)
Includes:
- Gas Burner
- Lava Rock
- Black Embers
- Fittings
- Flex Line
- Damper Clamp
- Vermiculite (LP only)
Purchase your Grand Canyon Two-Burner 42-inch Indoor Vented Natural Gas Burner 2BRN-42 and enjoy the beautiful-looking natural fire!
Features
Features:
- Style: Main rear burner w/Dual action front ember burner
- Standards: ANSI Certified with Control Systems
- Usage: Indoor
- Materials: Stainless Steel Chassis
- Warranty: Lifetime Warranty ? When Installed Indoors
- Piping: 1/2" Piping & 1?2" Bar Stock
- Fittings: Gas Inlet Left or Right
- Convertible to LP: NG Burner convertible to LP
- Media: Includes Lava Rock, Embers, & Connection Fittings
- Pilot: Concealed Pilot Mounting Brackets
- Design: Fully Welded System with Sandless Design
- Vent type: Vented
Manuals
Manuals:
- Indoor Product Catalog for Grand Canyon Two-Burner Indoor Vented Natural Gas Burner
- Burner Installation Manual for Grand Canyon Two-Burner Indoor Vented Natural Gas Burner
- Burner Specification Sheet for Grand Canyon Two-Burner Indoor Vented Natural Gas Burner
- Propane Conversion Kit Chart for Grand Canyon Two-Burner Indoor Vented Natural Gas Burner
- WeatherSmart App Setup Guide for Grand Canyon Two-Burner Indoor Vented Natural Gas Burner
- Millivolt Quick Mount Kit Manual for Grand Canyon Two-Burner Indoor Vented Natural Gas Burner
- Electronic Ignition System Manual for Grand Canyon Two-Burner Indoor Vented Natural Gas Burner
- Vented Control Valve Features and Breakdown for Grand Canyon Two-Burner Indoor Vented Natural Gas Burner
- Battery Powered Electronic Ignition System Manual for Grand Canyon Two-Burner Indoor Vented Natural Gas Burner
Need assistance? Talk to an Expert at +1-800-923-4556 or email: support@flameauthority.com to get the best-suited Vented Burner for your needs.
Specifications
Specifications:
- Size: 42"
- Front Width: 54"
- Depth: 16"
- Back Width: 42"
- Height: 14"
- BTU Rating: 86K (NG) 87K (LP)
- Sizing Chart
- 2 Burner Drawing CF
Vented Gas Log Set
Vented Gas Log Set:
42" Arizona Weathered Oak (AWO42LOGS)
42" Arizona Juniper (AJ42LOGS)
42" Quaking Aspen (ASPEN42LOGS)
42" Arizona Weathered Oak Charred (AWOC42LOGS)
42" Western Driftwood (DRIFTWOOD42LOGS)
Electronic Ignition Control Systems
Electronic Ignition Control Systems:
Battery Electronic MVKEIKN & MVKEIKLP
- Pilot: Non-Standing Pilot
- On-Demand System: Pilot On-Demand System
- Power: 2-D Cell Battery Electronic Ignition
- Design:
- Assembly:
- Operations: On/Off Operations ONLY
- Max Inlet 14? W.C.
- Valve: Valve Temp Rating 175?
- NG: (NG) 3?-7? W.C. 88,000 BTU?s
- LP: (LP) 8?-14? W.C. 110,000 BTU?s
- Valve Breakdown
110V Electronic Ignition EIS & EIS-LP
- Pilot: Non-Standing Pilot
- On-Demand System: Pilot On-Demand System
- Power: 24V Electronic Ignition
- Design: In-Wall Design
- Assembly: 6?-10? Pilot Assembly
- Operations: On/Off Operations ONLY
- Max Inlet 14? W.C.
- Valve: Valve Temp Rating 175?
- NG: (NG) 3?-7? W.C. 200,000 BTU?s
- LP: (LP) 8?-14? W.C. 110,000 BTU?s
- Valve Breakdown
Millivolt Control Systems
Millivolt Control Systems:
Modulating Millivolt MMVKR-NG & MMVKR-LP
- Pilot: Standing Pilot System
- On-Demand System:
- Power: Variable Flame Height
- Design: Low Profile Design
- Assembly:
- Operations:
- Max Inlet 14? W.C.
- Valve: Valve Temp Rating 225?
- NG: (NG) 7? W.C. 120,000 BTU?s
- LP: (LP) 7?-14? W.C. 120,000 BTU?s
- Valve Breakdown
On/Off Millivolt MVQMKN & MVQMKLP
- Pilot: Standing Pilot System
- On-Demand System:
- Power:
- Design: Low Profile Design
- Assembly:
- Operations: On/Off Operations ONLY
- Max Inlet 14? W.C.
- Valve: Valve Temp Rating 175?
- NG:(NG) 3?-5? W.C. 70,000 BTU?s
- LP:(LP) 8?-12? W.C. 110,000 BTU?s
- Valve Breakdown
On/Off High Output Millivolt HCMVQMKN & HCMVQMKLP
- Pilot: Standing Pilot System
- On-Demand System: Standing Pilot System
- Power: High Volume Output Millivolt System
- Design:
- Assembly:
- Operations: On/Off Operations ONLY
- Max Inlet 14? W.C.
- Valve: Valve Temp Rating 175?
- NG:(NG) 3?-5? W.C. 370,000 BTU?s
- LP:(LP) 8?-12? W.C. 560,000 BTU?s
- Valve Breakdown
Safety Pilot Control Systems
Safety Pilot Control Systems:
Safety Pilot SPQMKN & SPQMKLP
- Pilot: Standing Pilot System
- On-Demand System:
- Power:
- Design: Low Profile Design
- Assembly:
- Operations: Manual On/Off Operations ONLY
- Max Inlet 14? W.C.
- Valve: Valve Temp Rating 300?
- NG: (NG) 90,000 BTU?s
- LP: (LP) 90,000 BTU?s
- Valve Breakdown
High Output Safety Pilot HCSPK-N & HCSPK-LP
- Pilot: Standing Pilot System
- On-Demand System:
- Power:
- Design:
- Assembly:
- Operations: Manual On/Off Operations ONLY
- Max Inlet 14? W.C.
- Valve: Valve Temp Rating 250?
- NG: (NG) 124,000 BTU?s
- LP: (LP) 200,000 BTU?s
- Valve Breakdown
Manual Valve MA & MAHC-GC
- Pilot:
- On-Demand System:
- Power:
- Design: Low Profile Design
- Assembly:
- Operations: Manual On/Off w/ Knob or Wrench Operations ONLY
- Max Inlet 14? W.C.
- Valve: Valve Temp Rating 300?
- NG: 90,000 BTU?s (NG/LP) - MA
- LP: 240,000 BTU?s (NG/LP) - MAHC
- Valve Breakdown
Remotes & Controllers
Remotes & Controllers:
GCWS
- Basic On/Off Operations
- Rocker Switch & Cover Included
- 15? 10-2 low voltage wire
- Valve Breakdown
GCRK
- Basic On/Off Operations
- RF Transmitter & Receiver
- LCD Temp Display
- Includes Batteries & Wall Plate
- Valve Breakdown
GCRK-110
- Basic On/Off Operations
- 110V Plug-In
- RF Transmitter & Receiver
- Includes Batteries
- Valve Breakdown
WBPB-12/24
- Bluetooth | Wi-Fi & Manual Control
- Connect with Home Automation OR Weather Smart App
- 12/24V System
- Valve Breakdown
WASHING INSTRUCTIONS: